Focus: pre-order validation for adapters, indexes, primers, and probes
Use this guide when you need to validate adapters, dual indexes, amplicon primers, or capture probes before submitting an NGS order. It helps you check Tm, GC, secondary structure, and index compatibility early enough to catch weak adapter designs, barcode collisions, and panel-level bias before vendor submission.
Need the shorter task-specific page?
Use the Illumina adapter guide if you only need adapter and dual-index framing. Stay on this page if you need one pre-order validation guide that spans adapters, indexes, amplicon primers, and capture probes.
NGS library prep orders can mix several oligo families with different failure modes. The first job is to separate them by role so you validate the right properties for each one instead of applying one generic checklist to the whole submission.
| Oligo family | Length basis | Where it is used | What matters most | Best first tool |
|---|---|---|---|---|
| Y-adapters | Protocol-defined | Ligation-based library prep | Duplex stability, 3' end design, secondary structure | Structure Predictor |
| Dual indexes | Protocol-defined | Multiplexed sequencing | Uniqueness, Hamming distance, color balance, homopolymers | Batch Sequence QC |
| Amplicon primers | Assay-defined | Amplicon sequencing | Target-region Tm, GC, dimer risk, panel Tm spread | Tm Calculator |
| Capture probes | Workflow-defined | Hybrid capture | Panel-level Tm spread, GC bias, repeats, strong hairpins | GC Content Analyzer |
| Blocking oligos | Protocol-defined | Capture cleanup and suppression | Complementarity to adapter regions and Tm under the selected assay conditions | Tm Calculator |
Adapters fail when the duplex is weak, the ends do not match the ligation strategy, or the oligo folds back on itself before ligation or cluster generation. Validate the annealed region, not just the full sequence average.
| Adapter check | What to target | Why it matters |
|---|---|---|
| Annealed duplex Tm | Match the current library protocol and duplex design | Weak or mismatched duplexes can affect ligation or downstream cluster formation |
| 3' end configuration | Matches your end-prep strategy | Overhang mismatches or wrong blocking quietly break ligation |
| Secondary structure | Review strong hairpins and self-dimers under the selected working conditions | A folded adapter may change the available structure or interaction profile; confirm impact with the protocol and QC evidence |
| Purification level | Record the current supplier and protocol specification | Truncated products can change downstream behavior; confirm with the available QC evidence |
Indexes are a set-level problem. A single index can look fine by itself while the full set still fails because the barcodes are too similar, poorly balanced, or collision-prone on the target sequencer.
| Index rule | Target | Why it matters |
|---|---|---|
| Hamming distance | Use the sequencer and demultiplexing specification | The error-tolerance rule depends on the instrument and index design |
| Color balance | Check cycle balance against the platform protocol | Read quality depends on instrument chemistry and the full index set |
| GC content | Review composition under the platform and assay guidance | A generic GC cutoff does not establish index-read performance |
| Homopolymers | Review same-base runs with the platform guidance | A sequence flag does not prove a demultiplexing failure |
| Unique dual indexing | Use only when required by the selected workflow | Index-hopping mitigation depends on the complete protocol and cleanup workflow |
Treat the target-specific region and the full oligo differently. The target-specific region drives PCR annealing. The full oligo drives synthesis success and tail-related structure issues.
| Target-region Tm | Protocol and assay dependent |
| Target-region GC | Screen with the selected design method |
| Panel Tm spread | Compare under matched assumptions |
| Hairpin risk | Avoid stable structures in the full oligo |
| Amplicon size | Keep within the read strategy and assay goal |
Capture panels should be reviewed as a panel first. Probe-level outliers can affect observed on-target rate or coverage uniformity, so compare the selected workflow's measured criteria with probe-level flags rather than relying only on an average.
| Probe length | Use the selected capture workflow specification |
| GC content | Use the selected workflow's documented range |
| Tm spread | Compare the panel under matched assumptions |
| Repeat masking | Avoid probe placement in repetitive sequence |
| Secondary structure | Flag strong hairpins before ordering |
| Panel check | What to watch | Best first tool |
|---|---|---|
| Amplicon panel Tm spread | Identify outlier primer pairs before multiplexing | Tm Calculator |
| Probe-panel GC distribution | Find GC-heavy or GC-poor bins that will capture unevenly | GC Content Analyzer |
| Panel-level homopolymers or repeats | Remove synthesis-unfriendly probe or primer sequences | Batch Sequence QC |
| Strong structures in long oligos | Catch tails or probes that self-fold before they function | Secondary Structure Predictor |
Separate adapters, indexes, amplicon primers, capture probes, and blockers before you apply any thresholds.
Review the oligo map →Check the duplex or target-facing region that actually matters for the assay rather than averaging across the whole oligo.
Open Tm Calculator →Catch hairpins and dimers that reduce effective concentration before ligation, PCR, or capture.
Open Structure Predictor →Look for GC extremes, homopolymers, repeats, and set-level sequence issues before vendor submission.
Open Batch QC →Do the formatting step after sequence review so you do not keep regenerating vendor files during revision loops.
Open Vendor Format Adapter →Begin with the Tm Calculator for target-specific checks, then use Batch Sequence QC for panel review. If the file is ready and you only need the vendor format, finish in the Vendor Format Adapter.