OligoPool
PricingContactAbout
OligoPool

Free, professional tools for oligonucleotide design and analysis. Built for the molecular biology research community.

Contact OligoPool

Tools

  • Tm Calculator
  • GC Content Analyzer
  • Molecular Weight Calculator
  • Primer Analyzer
  • Batch Sequence QC
  • All 19 Tools

Guides

  • PCR Primer Design
  • Oligo Pool Synthesis
  • CRISPR Library Design
  • Melting Temperature
  • Oligo Quality Control
  • All Guides

Solutions

  • All Solutions
  • For Academic Labs
  • For Biotech
  • For Pharma R&D

Compare

  • vs IDT OligoAnalyzer
  • vs NEB Tm Calculator
  • Oligo Tool Suite
  • All Comparisons

Oligo Pools

  • Oligo Pool Design
  • How to Design
  • Vendor Decision

About

  • About Us
  • Contact
  • Pricing
  • Vendors
  • Resources
  • Privacy Policy
  • Terms of Service

© 2026 OligoPool.com. All rights reserved.

Partners:Oligo Pools
HomeToolsMolecular Weight Calculator

Oligo Molecular Weight Calculator - MW, OD260 & ε260

Calculate oligo MW, molecular weight, OD260, ε260 extinction coefficient, nmol, µg, and stock concentration conversions for DNA and RNA oligonucleotides. Use this single-metric workspace before dilution or full primer review.

Input Parameters

Length: 0 nt

Modifications (Optional)

End Modification
Affinity Tag
Fluorophore
Quencher
Linker
Backbone Modification
Terminal Protection

Results

No results yet

Enter a sequence and click"Calculate MW"

What Is Oligonucleotide Molecular Weight?

Molecular weight (MW) of an oligonucleotide is the sum of the atomic weights of the atoms represented by the sequence and selected chemistry, typically expressed in Daltons (Da) or grams per mole (g/mol). For a single-stranded DNA oligonucleotide, the result depends on sequence composition, terminal chemistry, salt form, and any supported modification.

MW helps convert between mass (µg) and molar (nmol, pmol) quantities when preparing stocks from a supplier-reported amount. The supplied record may use OD260, nanomoles, another unit, or a chemistry-specific convention; use the supplier specification when the exact delivered form matters.

The extinction coefficient (ε260) is equally important: it tells you how much UV light at 260 nm the oligo absorbs, allowing you to measure concentration using a spectrophotometer such as a NanoDrop. The calculator uses a sequence-type-specific nearest-neighbor ε260 table for DNA or RNA, which accounts for base stacking interactions instead of relying only on simple base-additive sums.

If you searched for oligo molecular weight calculator, calculate MW, OD260, and ε260 here before moving to dilution or full primer review.

This page should stay a single-metric MW and OD260 workspace. When the same sequence also needs Tm, GC%, hairpin, self-dimer, hetero-dimer, mismatch, or BLAST review, open the Primer Analyzer for the full OligoAnalyzer-style report instead of using this page as an all-in-one analyzer.

How to Use the Molecular Weight Calculator

  1. Enter your oligonucleotide sequence (5' to 3') in the input field. Both DNA and RNA are supported.
  2. Select any 5' or 3' modifications (phosphate, biotin) if applicable.
  3. The calculator instantly displays: molecular weight (Da), extinction coefficient (ε260 in L/(mol·cm)), nmol/OD260, and µg/OD260.
  4. To convert from OD260 to concentration: enter the measured OD260 value and resuspension volume to get the concentration in µM and ng/µL.
  5. This calculator accepts one sequence per calculation. For a list of sequences, use Batch Sequence QC for batch screening; it does not provide per-row MW or ε260 outputs.

Frequently Asked Questions

How is oligonucleotide molecular weight calculated?
The calculator applies its implemented nucleotide mass model to one DNA or RNA sequence and adds mass adjustments for selected supported modifications. The result is a model-based value; confirm the exact terminal chemistry, backbone, salt form, and modification specification against the supplier record when those details matter.
What is the extinction coefficient (ε260) and why does it matter?
The molar extinction coefficient (ε260) describes absorbance at 260 nm and is used with Beer-Lambert calculations. This calculator derives ε260 from the nucleotide sequence and selected DNA/RNA table using its implemented nearest-neighbor method; the selected modification mass adjustments do not add label-specific absorbance to ε260. Compare with the supplier value or a measured concentration when label chemistry or experimental conditions matter.
How do I convert OD260 to nmol or µg?
The calculator reports nmol and µg per OD260 from the selected sequence model. Multiply the measured OD260 by the corresponding displayed factor to estimate amount; divide the resulting amount by the solution volume to calculate concentration. Use a path-length-corrected absorbance and the relevant supplier or instrument guidance for your measurement.
Does salt form affect molecular weight?
Salt and counterion conventions can affect a reported molecular mass. This calculator reports the value produced by its implemented sequence and selected-modification model; it does not offer a salt-form selector. Check the supplier specification when you need the mass for a particular supplied form.
What are the limits of the ε260 estimate?
The value is calculated from the sequence using the tool's implemented nearest-neighbor table. It is not a measurement and does not model label-specific absorbance or experimental folding conditions. For modified oligos or a concentration-critical assay, compare with the supplier specification or an appropriate measurement.
Does the calculator process a batch of sequences?
No. This page calculates one sequence at a time. Batch Sequence QC screens multiple sequences for selected sequence-level flags, but does not replace this page's per-sequence molecular-weight and OD260 outputs.
When should I use Primer Analyzer instead of this MW calculator?
Use this page when mass, molecular weight, OD260, extinction coefficient, or stock concentration is the only task. Use the Primer Analyzer when MW needs to be reviewed together with Tm, GC%, hairpins, self-dimers, hetero-dimers, mismatch effects, BLAST review, and client-side detailed primer output.

Related Tools

Dilution Calculator

After calculating MW, use the dilution calculator to prepare stock solutions and working concentrations.

Tm Calculator

Calculate melting temperature alongside MW for complete primer characterization.

Primer Analyzer

Use the Primer Analyzer when MW should be reviewed together with Tm, GC%, hairpins, dimers, and mismatch effects.

Review request

Check a result or ordering detail

Send the calculation, settings, or pool submission detail that needs a second look.

Related reading

Continue with the page or tool that matches the next decision in your experiment.

Validate PCR Primers Before OrderingDesign GuideMethod References