Use this page after the main oligo pool guide to interpret a vendor QC sheet or NGS validation report for an oligo pool. It explains what representation, dropout, CV, Gini, fold-range, and error rate mean, plus how threshold decisions shift across CRISPR, NGS panels, mutagenesis, MPRA, and gene assembly work. When you need to screen the actual sequence set before ordering, run the Batch Sequence QC tool. If you need the cited threshold bands behind those calls, start from the QC thresholds by application research page.
Confirm the report's denominator, sequence map, read-filtering rules, sample type, and whether values are raw, normalized, or model-derived. The same metric label can describe different measurements when those definitions differ; record the method before comparing vendors, runs, or applications.

Next-Generation Sequencing (NGS) flow cell verification.
Use these rows as a fast interpretation layer when you open a vendor QC sheet or NGS readout. They are meant to help you triage which rows need more context or escalation, not to replace application-specific thresholds.
| Metric | What It Measures | Formula | Interpretation Prompt | Review Prompt | Escalate When |
|---|---|---|---|---|---|
| Representation | % of designed oligos detected | Detected / Designed × 100 | Most designed oligos are still present | Noticeable attrition but the pool is still broadly recoverable | Dropout clusters or the application-specific floor is missed |
| Dropout Rate | % of oligos completely absent | (Designed - Detected) / Designed | Missing sequences stay rare and scattered | Loss is visible but not yet dominant | Whole sequence classes disappear or library bottlenecks become obvious |
| Uniformity (CV) | Read count variation | StdDev / Mean of reads | Read-count spread stays relatively tight | A long tail is forming but does not dominate the pool | Severe outliers or a broad tail are likely to distort downstream use |
| Gini Coefficient | Distribution inequality | Lorenz curve calculation | Counts are fairly even across the pool | Meaningful skew is emerging in the read distribution | A small subset of oligos is dominating the library |
| Error Rate | Report-defined sequence error burden | Use the report's definition | Compare the reported measure with the assay criteria | Investigate the error categories and filtering assumptions | The documented error burden conflicts with the planned use case |
| Fold-Range | Max/min read count spread | Max reads / Min reads | No extreme max/min outliers are visible | Outliers exist but do not yet define the pool | A few sequences swamp the library while others are barely detectable |
The same pooled readout should not be judged with one universal cutoff. This table gives a starting QC question for each application; use the assay plan and cited sources to decide what matters for the project. For published threshold bands and source trails, open the QC thresholds by application research page.
| Application | First Review Focus | Why It Can Matter | When to Escalate into Evidence |
|---|---|---|---|
| CRISPR KO Screen | Coverage and representation through selection | Abundance loss can look like biology when coverage is too thin | When you need published pooled-screen coverage floors |
| CRISPRa/i Screen | Coverage plus uniformity across subtle phenotypes | Small effect sizes make bottlenecks harder to spot from summary averages alone | When the screen design needs stronger published coverage guidance |
| NGS Capture Panel | Panel balance and on-target performance | Uniform presence matters more than one generic pooled-library cutoff | When assay validation needs to be separated from generic pool QC |
| DMS / Mutagenesis | Variant or barcode read depth plus uniformity | Under-sampled variants distort enrichment scores and frequency calls | When you need published DMS or mutagenesis depth bands |
| Gene Assembly | Post-correction error burden | Sequence accuracy dominates rework cost once constructs get longer | When the pool is being evaluated for synthesis-error burden rather than screening balance |
| MPRA | Barcode complexity with matched DNA and RNA coverage | Barcode loss destabilizes activity estimates even when total reads still look high | When you need published barcode-support filters and QC interpretation notes |
Use the sequencing plan defined for the assay. Map reads to designed sequences with a validated workflow, then count reads per oligo.
Count oligos with ≥1 read and divide by total designed oligos. Investigate missing sequences against the assay criteria before deciding whether redesign is needed.
When compatible read-count data are available, compute CV (StdDev/Mean), Gini coefficient, and fold-range from the distribution. The report definition and filtering method remain part of the result.
Use Uniformity Estimator →Record how the supplier or sequencing workflow defines errors, then compare the reported categories with the assay criteria. The Error Rate Calculator is a theoretical coupling model, not a read-alignment validator.
Use Error Rate Calculator →Compare array and column synthesis when QC expectations differ.
Compare sequence constraints with the selected assay and current supplier requirements.
Compare observed findings with the report method, assay plan, and supplier evidence.
Review a fixed-assumption scenario; it is not measured pool uniformity.
Screen the sequence set with selected GC, Tm, homopolymer, length, and structure checks before review.
Explore a coupling-only scenario from entered assumptions; it is not measured yield.
Check the literature-backed threshold bands behind CRISPR, DMS, MPRA, and gene-assembly QC decisions.
See how vendors differ on QC depth, included validation, and fit.